Download Print this page

INVT Goodrive350 Series Operation Manual page 177

Ip55 high-ingress protection vfd
Hide thumbs Also See for Goodrive350 Series:

Advertisement

Goodrive350 IP55 High-ingress Protection Series VFD
Function
Name
code
P05.37 AI2 input filter time
HDIA high-speed
P05.38
pulse input function
selection
HDIA frequency
P05.39
lower limit
Corresponding
P05.40
setting of HDIA
frequency lower
Description
100%
-10V
Input filter time: to adjust the sensitivity of
analog input. Increasing the value properly can
enhance analog input anti-interference but may
reduce the sensitivity of analog input.
Note: AI1 supports the 0–10V/0–20mA input.
When AI1 selects the 0–20mA input, the
corresponding voltage of 20mA is 10V. AI2
supports the -10–+10V input.
Setting range of P05.24:
Setting range of P05.25: -300.0%–300.0%
Setting range of P05.26: P05.24–10.00V
Setting range of P05.27: -300.0%–300.0%
Setting range of P05.28: 0.000s–10.000s
Setting range of P05.29:
Setting range of P05.30: -300.0%–300.0%
Setting range of P05.31:
Setting range of P05.32: -300.0%–300.0%
Setting range of P05.33:
Setting range of P05.34: -300.0%–300.0%
Setting range of P05.35: P05.33–10.00V
Setting range of P05.36: -300.0%–300.0%
Setting range of P05.37: 0.000s–10.000s
0: Input set through frequency
1: Reserved
2: Input set through encoder, used together with
HDIB
0.000kHz –
P05.41
-300.0%–300.0%
-159-
Corresponding
setting
AI2
0
10V
-100%
0.00V–P05.26
-10.00V–P05.31
P05.29–P05.33
P05.31–P05.35
Function parameter list
Default Modify
0.030s
0
0.000
kHz
0.0%

Advertisement

loading
Need help?

Need help?

Do you have a question about the Goodrive350 Series and is the answer not in the manual?