Goodrive350 IP55 High-ingress Protection Series VFD
circuit and chassis of each VFD before delivery. In addition, voltage limiting circuits that can
automatically cut off the test voltage are configured inside the VFDs.
Note: Before connecting the input power cable of the VFD, check the insulation conditions of
the cable according to local regulations.
VFD model
GD350-004G/5R5P-45-AS
GD350-004G/5R5P-45-NS
GD350-5R5G/7R5P-45-AS
GD350-5R5G/7R5P-45-NS
GD350-7R5G/011P-45-AS
GD350-7R5G/011P-45-NS
GD350-011G/015P-45-AS
GD350-011G/015P-45-NS
GD350-015G/018P-45-AS
GD350-015G/018P-45-NS
GD350-018G/022P-45-AS
GD350-018G/022P-45-NS
GD350-022G/030P-45-AS
GD350-022G/030P-45-NS
GD350-030G/037P-45-AS
GD350-030G/037P-45-NS
GD350-037G/045P-45-AS
GD350-037G/045P-45-NS
GD350-045G/055P-45-AS
GD350-045G/055P-45-NS
GD350-045G/055P-45-AS-B
GD350-045G/055P-45-NS-B
GD350-055G/075P-45-AS
GD350-055G/075P-45-NS
GD350-055G/075P-45-AS-B
GD350-055G/075P-45-NS-B
GD350-075G/090P-45-AS
GD350-075G/090P-45-NS
GD350-075G/090P-45-AS-B
Table D-1 Recommended cable size
Recommended cable size
(mm² )
R, S, T
U, V, W,
3×1.5/3×2.5
3×2.5/3×4
3×4/3×6
3×6/3×10
3×10/3×10
3×10/3×16
3×16/3×16
3×16/3×25
3×25/3×35
3×35/3×50
3×50/3×70
3×70/3×95
-381-
Optional peripheral accessories
Fixing screw
Terminal
PE
screw
1.5/2.5
M4
2.5/4
4/6
6/10
M5
10/10
10/16
16/16
16/16
M6
16/16
16/25
M8
25/35
35/50
M12
Fastening
torque (Nm)
1.2
2.3
2.5
10
35