Goodrive350 IP55 High-ingress Protection Series VFD
Function
code
Running frequency at
P07.49
Ramp reference frequency
P07.50
at 2nd-last fault
Output voltage at 2nd-last
P07.51
Output current at 2nd-last
P07.52
Bus voltage at 2nd-last
P07.53
Temperature at 2nd-last
P07.54
Input terminal state at
P07.55
Output terminal state at
P07.56
5.5.20 Tension control solutions
In many fields of industrial production, precise tension control is needed to maintain a constant
output tension of the drive equipment, in order to improve the quality of the products. In the
winding and unwinding of some industries such as paper processing, printing and dyeing,
packing, wire and cable manufacturing, textile, fiber, optic cable, leather, metal foil material
processing and so on, tension needs to keep constant.
The VFD controls the tension through the output torque or speed of the motor. There are three
kinds of control modes: tension speed control mode, open loop tension torque control mode
and close-loop tension torque control mode.
Name
2nd-last fault
fault
fault
fault
fault
2nd-last fault
2nd-last fault
Description
0.00Hz–P00.03
0.00Hz–P00.03
0–1200V
0.0–6300.0A
0.0–2000.0V
-20.0–120.0° C
0x0000–0xFFFF
0x0000–0xFFFF
-119-
Basic operation guidelines
Default
0.00Hz
0.00Hz
0V
0.0A
0.0V
0.0° C
0x0000
0x0000