Emerson R&S SGT100A User Manual page 67

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
Settings:
Instrument/Connection
Maximum
Pulse
Instrument Name / IP
Freq/Freq
RF
On/Off......................................................................................................................68
I/Q Mod
Level/Level
Ref. Oscillator Source/Ext Ref
LO Scr
Instrument/Connection State
The three colors of the state indicator in front of the instrument's name distinguish
between the following states:
Gray: the instrument is configured and activated in the R&S SGMA-GUI software
but there is no connection to the instrument.
Green: the instrument is active, the connection is working and the instrument can
be manually and remotely operated.
Red: the instrument is in one of the following states:
Maximum Frequency
The numbers in the rectangular box
maximum frequency of the instrument.
Pulse Modulation
A
switched on.
Instrument Name / IP Address
Displays the alias name of the instrument and the IP address, as set by the parameters
in "SGMA-GUI > Setup > Instruments > Add/Edit Instruments" dialog.
Click the key to access a menu tree for configuring the available instrument's settings,
e.g. "Level" settings.
Freq/Freq (Offs)
For R&S SGT, sets the RF frequency, incl. enabled frequency offset.
The following apples:
"Freq" =
User Manual 1176.8674.02 ─ 12
State.........................................................................................67
Frequency.....................................................................................................67
Modulation...........................................................................................................67
Address...................................................................................... 67
(Offs).............................................................................................................67
State................................................................................................................ 68
Offset..........................................................................................................68
Ext.....................................................................................................................69
Standby state
To operate the instrument manually, it has to be switched to ready state (see
"To return the instrument from standby to ready state"
Instrument locked
The red state indication together with the message "Instrument Locked" in the
"Info" line indicates that the instrument is locked for
another R&S SGMA-GUI software or controller.
The instrument is performing a time consuming operation, e.g. a selftest.
sign on the left of the instrument's name indicates that the pulse modulation is
Frequency
+
Offset
Understanding R&S SGMA-GUI
On/Off........................................................................... 68
on the left of the instrument's name indicate the
Main panel
on page 307).
Exclusive Access
from
67