Emerson R&S SGT100A User Manual page 431

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
Example:
Usage:
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:CATalog?
Queries the available settings files in the specified default directory. The settings files
are used to set the ARB multi carrier submenu. Only files with the file extension
*.arb_multcarr will be listed.
Return values:
<Catalog>
Example:
Usage:
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:LOAD <Filename>
Loads the settings file. If a settings file with the specified name does not yet exist, it is
created. The file extension may be omitted. Only files with the file extension
*.arb_multcarr will be loaded or created.
Setting parameters:
<Filename>
Example:
Usage:
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:STORe <Filename>
The command stores the current settings of submenu "Multi Carrier" in a file in the
specified directory. The file extension may be omitted, the files are stored with the file
extension *.arb_multcarr.
Setting parameters:
<Filename>
User Manual 1176.8674.02 ─ 12
BB:ARB:MCAR:SAMP?
queries the file size of the currently calculated multi carrier
waveform.
Query only
See
"File Size"
on page 111
string
MMEM:CDIR '/var/user/waveform'
sets the default directory
BB:ARB:MCAR:SETT:CAT?
reads out all the settings files in the default directory.
Response: mcar1, mcar2
the directory contains the configuration files
mcar1.arb_multcarr and mcar2.arb_multcarr.
Query only
See
"Save/Recall Frame"
string
BB:ARB:MCAR:SETT:LOAD '/var/user/new'
creates settings file new.arb_multcarr.
Setting only
See
"Save/Recall Frame"
string
Remote control commands
SOURce subsystem
on page 106
on page 106
431