Emerson R&S SGT100A User Manual page 440

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
Example:
Usage:
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CATalog?
Queries the available configuration files in the specified default directory. The configu-
ration files are used to create multi segment waveform files.
Return values:
<Catalog>
Example:
Usage:
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk <Clock>
This command defines the clock rate used for multi segment waveform output in case
of Clock Mode "User" (:BB:ARB:WSEG:CONF:CLOCk:MODE USER).
Parameters:
<Clock>
Example:
Manual operation:
User Manual 1176.8674.02 ─ 12
SOUR:BB:ARB:WSEG:CONF:SEL "MSegFile"
selects a multi segment file.
SOUR:BB:ARB:WSEG:CONF:BLAN:APP 1000,100000000
adds a blank segment with 1000 samples and 100 MHz clock
rate to the selected multi segment file
Setting only
See
"Clock Rate"
on page 99
See
"Samples"
on page 99
See
"Append Blank"
on page 99
string
MMEM:CDIR '/var/user/waveform'
sets the default directory.
BB:ARB:WSEG:CONF:CAT?
reads out all the configuration files in the default directory.
Response: mulit1, multi2
the directory contains the configuration files multi1.inf_mswv
and multi2.inf_mswv.
Query only
See
"Load List"
on page 96
float
Increment: 1E-3
*RST:
max SampleRate
BB:ARB:WSEG:CONF:CLOC:MODE USER
selects Clock Mode User.
BB:ARB:WSEG:CONF:CLOC 50MHz
defines a clock rate of 50 MHz.
See
"User Clock Rate"
Remote control commands
SOURce subsystem
on page 101