Emerson R&S SGT100A User Manual page 399

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
Return values:
<Sum>
Example:
Usage:
Manual operation:
[:SOURce<hw>]:AWGN:POWer:SUM:PEP?
In Additive Noise and CW Interferer (SOUR:AWGN:MODE ADD|CW) modes, queries the
peak envelope power of the overall signal comprised of noise signal plus useful signal.
Return values:
<Pep>
Example:
Usage:
Manual operation:
[:SOURce<hw>]:AWGN:STATe <State>
Activates or deactivates the white noise (AWGN = Averaged White Gaussian Noise).
Use the command
erator is working in.
Parameters:
<State>
Example:
Manual operation:
User Manual 1176.8674.02 ─ 12
float
Range:
-145 to 20
Increment: 0.01
*RST:
0
SOURce:AWGN:POWer:SUM?
queries the overall power of the noise signal plus useful signal.
Query only
See
"Carrier + Noise Power / Signal + Noise Power (System
Bandwidth) / Carrier + Interferer Power / Signal + Interferer
Power"
on page 150
float
Range:
-145 to 20
Increment: 0.01
*RST:
0
SOURce:AWGN:POWer:SUM:PEP?
queries the peak envelope power of the overall signal.
Query only
See
"Carrier + Noise PEP / Signal + Noise PEP (Total Band-
width) / Carrier + Interferer PEP / Signal + Interferer PEP"
on page 150
[:SOURce<hw>]:AWGN:MODE
0 | 1 | OFF | ON
*RST:
0
SOURce:AWGN:STATe ON
See
"State"
on page 144
Remote control commands
SOURce subsystem
to define the mode the AWGN gen-
399

Advertisement