User Clock Rate; Segment Marker; Sequence Restart - Emerson R&S SGT100A User Manual

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
"Unchanged"
"Highest"
"User"
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk:MODE
on page 441

User Clock Rate

Requires "Clock Mode > User".
Defines the sample rate used for multi-segment waveform output.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk

Segment Marker

Defines the way the marker information within the separate segments is processed.
"Ignore"
"Take Over"
Remote command:
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:MARKer:MODE
on page 443

Sequence Restart

Enables/disables the generation of an additional marker restart signal in the output
waveform file.
If additional marker generation is enabled, the existing marker signals in the individual
segment waveform files are not considered.
"Disable"
"Marker
1/2/3/4"
User Manual 1176.8674.02 ─ 12
A segment is output with the clock rate defined in the file.
If segments have different clock rates, extended trigger mode "Next
Segment" allows internal segment switchovers only ("Internal" trigger
source).
Extended trigger mode "Next Segment Seamless" can only be
selected if all segments have the same clock rate.
All segments are output at the highest available clock rate.
This mode provides short switchover times between segments.
The time for calculating the multi-segment waveform is increased
since the individual segments have to be resampled.
All segments are output at the clock rate defined in "User Clock".
This mode provides short switchover times between segments.
The time for calculating the multi-segment waveform is increased
since the individual segments have to be resampled.
The marker information carried in the individual segment waveform
files is not considered.
The output waveform file contains the marker information as config-
ured in the individual waveform files.
No additional marker is generated.
Generates a restart marker signal at the beginning of the first seg-
ment for the corresponding marker.
Use this setting to generate a restart marker for the complete
sequence.
Signal generator settings
Baseband
on page 440
101