SGT100A
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:SETTing:DELete <Filename>
Deletes the selected file from the default or specified directory. Deleted are files with
the file extension *.iqout.
Setting parameters:
<Filename>
Usage:
Manual operation:
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:TYPE <Type>
Sets the type of the analog signal.
Parameters:
<Type>
Example:
Manual operation:
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:BIAS:COUPling[:STATe] <State>
Couples the bias setting of the I and Q signal components.
Parameters:
<State>
Example:
Manual operation:
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:BIAS:I <I>
[:SOURce<hw>]:IQ:OUTPut[:ANALog]:BIAS:Q <Q>
Specifies the amplifier bias V
The value range is adjusted so that the maximum overall output voltage does not
exceed 4V, see
Parameters:
<Q>
User Manual 1176.8674.02 ─ 12
"<filename>"
Filename or complete file path
Setting only
See
"Save/Recall"
SINGle | DIFFerential | DAC
*RST:
SINGle
SOURce1:IQ:OUTPup:ANALog:TYPE DIFFerential
See
"I/Q Output Type"
1 | ON | 0 | OFF
*RST:
0
See
Example"Enabling and configuring the analog output"
on page 481.
See
"Couple I/Q Bias"
of the respective I or Q component.
bias
"Maximum overall output voltage"
float
Range:
-3.6V to 3.6V
Increment: 1E-4
*RST:
0
Default unit: V
Remote control commands
on page 162
on page 162
on page 163
on page 161.
SOURce subsystem