Emerson R&S SGT100A User Manual page 423

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
Parameters:
<Power>
Example:
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:POWer:REFerence <Reference>
Defines the way the individual carriers in a composed multi carrier signal are leveled.
Parameters:
<Reference>
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CARRier<ch>:STATe <State>
Enables/disables the selected carrier.
Parameters:
<State>
Example:
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:CFACtor:MODE <Mode>
The command sets the mode for optimizing the crest factor by calculating the carrier
phases.
Parameters:
<Mode>
User Manual 1176.8674.02 ─ 12
float
Range:
-80 to 0
Increment: 0.01
*RST:
0
Default unit: dB
BB:ARB:MCAR:CARR15:POW -50 dB
sets the power of carrier 15 to -50 dB.
See
"Gain"
on page 115
RMS | PEAK
*RST:
RMS
See
"Power Reference"
0 | 1 | OFF | ON
*RST:
0
SOURce1:BB:ARBitrary:MCARrier:CARRier15:STATe
ON
See
"State"
on page 115
OFF | MIN | MAX
OFF
There is no automatic setting for minimizing or maximizing the
crest factor. The Phase setting (command
BB:ARB:MCAR:CARR:PHAS) is in use.
MIN
The crest factor is minimized by internally calculating optimized
carrier phases. The Phase setting (command
BB:ARB:MCAR:CARR:PHAS) is invalid.
Remote control commands
SOURce subsystem
on page 110