Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
Example: Performing a power measurement with a fixed filter
Prerequisite: The sensor is connected to the instrument and mapped to the first sensor
channel.
SENSe1:SOURce RF
// Sensor measures the power of the RF signal.
SENSe1:FILTer:TYPE NSRatio
// Selects fixed noise filter mode.
SENSe1:FILTer:NSRatio 0.02 DB
// Sets the maximum noise component in the result to 0.02 DB.
SENSe1:FILTer:NSRatio:MTIMe 10
//Limits the settling time to 10 seconds.
SENSe1:APERture:DEFault:STATe 0
// Deactivates the default aperture time of the sensor.
SENSe1:APERture:TIMe 10e-6
// Sets the aperture time to 10 us.
SENSe1:UNIT DBM
// Selects unit dBm for the measured value.
INITiate:CONTinuous ON
// Switches the continous power measurement on.
READ?
// Triggers the measurement and displays the results.
:SLISt[:LIST]?
:SLISt:SCAN[:STATe]
:SLISt:SCAN:LSENsor
:SLISt:SCAN:USENsor
:SLISt:CLEar:LAN
:SLISt:CLEar:USB
:SLISt:CLEar[:ALL]
:SLISt:ELEMent<ch>:MAPPing
:SLISt:SENSor:MAP
:INITiate<hw>[:POWer]:CONTinuous
:READ<ch>[:POWer]?
:SENSe<ch>:UNIT[:POWer]
:SENSe<ch>[:POWer]:APERture:DEFault:STATe
:SENSe<ch>[:POWer]:APERture:TIMe
:SENSe<ch>[:POWer]:CORRection:SPDevice:SELect
:SENSe<ch>[:POWer]:CORRection:SPDevice:STATe
:SENSe<ch>[:POWer]:CORRection:SPDevice:LIST?
:SENSe<ch>[:POWer]:DISPlay:PERManent:PRIority
:SENSe<ch>[:POWer]:DISPlay:PERManent:STATe
:SENSe<ch>[:POWer]:FILTer:LENGth:AUTO?
User Manual 1176.8674.02 ─ 12
................................................................................................................ 378
......................................................................................................378
....................................................................................................378
................................................................................................... 379
.......................................................................................................... 379
..........................................................................................................379
.........................................................................................................380
........................................................................................380
.......................................................................................................380
............................................................................... 380
.................................................................................................... 381
............................................................................................381
.............................................................................382
Remote control commands
SENSe, READ, INITiate and SLISt subsystems
.............................................................. 382
.......................................................382
........................................................ 383
.........................................................383
.........................................................383
........................................................... 383
.................................................................. 384
377

Advertisement

Table of Contents
loading

Table of Contents