[:SOURce]:POWer:SERVoing:STATe <State>
Activates/deactivates power servoing.
Parameters:
<State>
Manual operation:
[:SOURce]:POWer:SERVoing:TARGet <Targetlevel>
Sets the target output power level required at the DUT.
Parameters:
<Targetlevel>
Manual operation:
[:SOURce]:POWer:SERVoing:TEST?
Queries the state of the power servoing procedure.
Return values:
<Start>
Usage:
Manual operation:
[:SOURce]:POWer:SERVoing:TOLerance <Tolerance>
Sets the tolerance level interval, in which the "Target" output power level of the DUT
lies.
A large tolerance accelerates the power servoing procedure but also reduces the accu-
racy of the target output power level.
Parameters:
<Tolerance>
Manual operation:
User Manual 1176.8674.02 ─ 12
See
"Start"
on page 242
1 | ON | 0 | OFF
*RST:
0
See
"State"
on page 241
float
Range:
-120 to 25
Increment: 0.01
*RST:
n.a. (factory preset: -10)
See
"Target"
on page 241
0 | 1 | RUNning | STOPped
*RST:
n.a. (no preset. default: STOPped)
Query only
See
"Run Test"
on page 299
float
Range:
0.01 to 3
Increment: 0.01
*RST:
n.a. (factory preset: 0.1)
See
"Tolerance"
on page 242