Emerson R&S SGT100A User Manual page 405

Sgma vector rf source
Table of Contents

Advertisement

®
R&S
SGT100A
Manual operation:
[:SOURce<hw>]:BB:ARBitrary:CLOCk:SYNChronization:EXECute
Performs automatically adjustment of the instrument's settings required for the syn-
chronization mode, set with the command
SYNChronization:MODE.
Example:
Usage:
10.14.4.3
Trigger commands
The TRIGger subsystem contains the commands for setting the trigger.
For option R&S SGT-K540, the ARB waveform for the envelope tracking (SOURce2)
uses the same trigger settings as the first ARB waveform (SOURce1). Therefore these
commands are not defined for SOURce2.
[:SOURce<hw>]:BB:ARBitrary:TRIGger:ARM:EXECute
[:SOURce<hw>]:BB:ARBitrary:TRIGger:EXECute
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:SYNChronize:OUTPut
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay:MAXimum?
[:SOURce<hw>]:BB:ARBitrary:TRIGger:OUTPut<ch>:DELay:MINimum?
[:SOURce<hw>]:BB:ARBitrary:TRIGger:RMODe?
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLENgth
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLUNit
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SMODe
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SOURce
[:SOURce<hw>]:BB:ARBitrary:TRIGger:DELay:UNIT
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal<1|2>]:DELay
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal<1|2>]:TDELay
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal<1|2>]:RDELay?
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal<1|2>]:INHibit
[:SOURce<hw>]:BB:ARBitrary[:TRIGger]:SEQuence
User Manual 1176.8674.02 ─ 12
SECondary
The instrument receives the synchronisation and reference clock
signal from another instrument working in primary mode.
DIIN
The instrument receives the synchronisation and reference clock
signal from the "DIG I/Q" connector.
*RST:
NONE
See
"Sync Mode"
on page 133
[:SOURce<hw>]:BB:ARBitrary:CLOCk:
BB:ARB:CLOC:SYNC:MODE PRIM
the instrument is configured to work as a primary instrument.
BB:ARB:CLOC:SYNC:EXEC
all synchronization's settings are adjusted accordingly.
Event
............................................................. 406
............................................................. 407
..............................................................408
................................................................ 408
............................................................... 409
..............................................................409
Remote control commands
SOURce subsystem
..................................................... 406
...........................406
........................... 407
.............................407
........................................................ 409
.........................................410
.......................................410
.....................................410
......................................... 411
......................................................... 411
405

Advertisement

Table of Contents
loading

Table of Contents