Nortel Millennium M1000 Manual page 89

Multi-pay-based terminal replacing part
Table of Contents

Advertisement

rprbk203 Page 21 Tuesday, February 16, 1999 9:12 AM
3. Lift up the flap and remove the SAM by sliding it up and
out of the housing.
4. Put the module you remove in a secure, static-free
place.
5. Install the new SAM into the socket.
Refer to Figure 3-11 for proper positioning of the SAM
into the socket.
Warning
Note: The SAM can only go in one
way.
It should slide in easily and snugly.
Do not try to force it into the socket if
it does not seem to fit.
If it is too loose, use another SAM or
replace the daughter board.
6. Close the socket and slide the lock back in place.
7. If you removed it, replace the control PCP into the PCP
assembly and the PCP assembly into the terminal.
8. Restore the terminal to operation.
Refer to Restoring the terminal to operation on
page 2-10, if necessary.
a) Reconnect the power to the terminal by recon-
necting the terminal block to the rear terminal PCP.
b) Remove your ESD strap connection.
c) Close and lock the terminal.
9. Follow the procedures in SmartCity — checking
SAM function on page 3-25.