Nortel Millennium M1000 Manual page 195

Multi-pay-based terminal replacing part
Table of Contents

Advertisement

rprbk203 Page 13 Tuesday, February 16, 1999 9:12 AM
b) Locate the partition tab which extends through the
wall of the rejection chute. Refer to Figure 6-11.
c) Bend the tab straight.
d) Slide the partition out and discard.
e) Re-attach the coin rejection chute to the validator
body, making sure all the tabs are inserted in the
proper holes.
13. To replace the validator in the terminal, reverse the
preceding steps.
a) When replacing the validator, it may be necessary
to detach the link assembly.
If necessary, refer to Replacing the front housing
assembly on page 2-13.
b) Slide the bottom of the validator coin chute into the
top of the coin chute on the escrow.
Refer to Figure 6-12.
c) At the same time, slip the large part of the keyhole
over the retaining screw.
Refer to the inset in Figure 6-12.
d) Slide the validator into position.
e) Replace the front housing if you removed it in
step 13a.
f) Reinstall the PCP assembly if you removed it at the
beginning of this procedure.
Ensure that you route the ribbon cable from the
validator (J33) under the PCP assembly.
Refer to Removing the PCP assembly on page 3-
2, if necessary.
Millennium Multi-pay-based terminals: replacing parts
Coin path modules 6-13