Nortel Millennium M1000 Manual page 66

Multi-pay-based terminal replacing part
Table of Contents

Advertisement

rprbk203 Page 38 Tuesday, February 16, 1999 9:12 AM
2-38 Accessing the terminal
Figure 2-24: Connecting to the rear terminal PCP
Terminal block (J2)
connections
Connect
this last, as
this connects
power to
the terminal
NTP: 506-6501-203 Issue: 00.01 Status: Standard Date: June 1998
CAUTION
• Ensure the proper polarity
when connecting the supple-
mentary power supply. The ter-
minal does not work if the
polarity is incorrect.
• Take the usual precautions
with the wiring.
Connecting
• Conceal the wiring near the
live wires to the
telephone or use approved
terminal
moulding or tubing.
• Locate protectors and connect-
ing blocks where they will be in-
accessible to the terminal user.
d) Connect the interconnect cable wires to the upper
terminal block for the rear terminal PCP (J28).
Refer to Figure 2-24.
J2
J1
Interconnect
cable
connects
between
these two
connectors
IAS module
Interconnect
cable connector (J1)
(connects to terminal
block on rear terminal
PCP)
Terminal block
(J28)
Rear terminal PCP