Nortel Millennium M1000 Manual page 164

Multi-pay-based terminal replacing part
Table of Contents

Advertisement

rprbk203 Page 22 Tuesday, February 16, 1999 9:12 AM
5-22 Card and hookswitch parts
Figure 5-19: Bezel A alerter connector on keypad PCP
Alerter PCP
Cable clamp
Keypad PCP
Hookswitch
PCP
NTP: 506-6501-203 Issue: 00.01 Status: Standard Date: June 1998
2. Disconnect the alerter cable.
If the alerter cable (J14) is connected to the key-
pad PCP: remove the PCP assembly bracket as
explained in Removing the PCP assembly on
page 3-2 and put it in an anti-static bag and set it
aside.
Refer to Figure 5-19.
Note: If the alerter is connected to a smart card
alert daughter board disconnect J14 from J37 on
the smart card alert daughter board.
If the keypad PCP is attached to the external inter-
face hookswitch module with a mylar ribbon cable,
then the alerter is connected to the hookswitch
module if there is no smart card alert.
Refer to Figure 5-20.
J51
J52

Advertisement