Nortel Millennium M1000 Manual page 196

Multi-pay-based terminal replacing part
Table of Contents

Advertisement

rprbk203 Page 14 Tuesday, February 16, 1999 9:12 AM
6-14 Coin path modules
Figure 6-12: Reinstalling the validator
Validator
Validator
coin return
chute
Validator slides
into escrow
chute
Escrow
NTP: 506-6501-203 Issue: 00.01 Status: Standard Date: June 1998
14. Restore the terminal to operation.
Refer to Restoring the terminal to operation on
page 2-10, if necessary.
a) Reconnect the power to the terminal by recon-
necting the terminal block to the rear terminal PCP.
b) Remove your ESD strap connection.
c) Close and lock the terminal.
d) If you replaced the validator with a new one, run
the INSTALL routine.
e) If you installed the original validator back into the
terminal, run the craft interface coin tests to ensure
the coin path is clear.
15. Perform function tests.
Keyhole
Coin
validator
retaining
screw