Nortel Millennium M1000 Manual page 43

Multi-pay-based terminal replacing part
Table of Contents

Advertisement

rprbk203 Page 15 Tuesday, February 16, 1999 9:12 AM
confirmed that the terminal block is disconnected
from the rear terminal PCP
See this
• Before disconnecting any ca-
• Do not reconnect power until
Failure to follow these precautions may damage
ESD-sensitive components.
2. Disconnect the control PCP cables for rear housing
components:
a) Disconnect the rear terminal PCP cable (J18) from
the control PCP connector.
b) Disconnect the coin validator cable (J33) from the
control PCP connector (J8).
Refer to Figure 2-6.
3. With the terminal open, you will see that the front hous-
ing is supported by a link assembly tie-rod.
This flat, jointed rod hooks onto a bracket at the top of
the rear housing and about mid-way in the center of
the front housing.
Refer to Figure 2-6.
Remove the link assembly arm from one of the brack-
ets in the following manner:
a) While supporting the front housing assembly, lift
the link assembly until the top link is loose and
almost parallel to the top of the housing, as shown
in Figure 2-7.
b) Move the top link upward and sideways so the slot
on the tie-rod aligns with the pivot tab.
c) Release the link.
Millennium Multi-pay-based terminals: replacing parts
Accessing the terminal 2-15
bles, disconnect the supplemen-
tary power supply.
you are ready to close the ter-
minal.

Advertisement

Table of Contents
loading