Nortel Millennium M1000 Manual page 67

Multi-pay-based terminal replacing part
Table of Contents

Advertisement

rprbk203 Page 39 Tuesday, February 16, 1999 9:12 AM
Ensure you maintain the proper Tip and Ring
connections.
If you are replacing the module, the interconnect
cable should already be wired.
e) Connect the upper terminal block to the rear
terminal PCP (J28). Refer to Figure 2-24.
Position the cable along the back of the terminal so
that it does not interfere with the PCP assembly
when the housing is closed.
4. Restore the terminal to operation.
Refer to Restoring the terminal to operation on
page 2-10, if necessary.
a) Reconnect the power to the terminal by recon-
necting the terminal block to the IAS module.
b) Route the ISW to the bottom of the rear housing to
prevent interference with the PCP assembly.
c) To prevent the IAS PCP from sliding up in its
mount, insert a cable tie through the hole at the top
of the board mount and tie its ends together.
d) Remove your ESD strap connection.
e) Close and lock the terminal.
5. Run the answer supervision test in the craft interface
to test the module.
Millennium Multi-pay-based terminals: replacing parts
Accessing the terminal 2-39