To configure a PCoIP Zero Client with an endpoint manager in low or medium security mode:
1. From the AWI, select Configuration > Management. The AWI Management page displays.
2. Set the Security Level option to Low or Medium.
3. Set the Manager Discovery Mode to Manual.
4. In the Manual Discovery section, type the bootstrap server's URI.
Bootstrap server URI must use a secured WebSocket prefix
URIs are in this format and require a secured WebSocket prefix:
FQDN>[:port number]
port 5172 will be used by default.
5. Click Apply.
After the Tera2 PCoIP Zero Client discovers the endpoint manager, the endpoint manager topology
appears on the Management page.
Discovering the Endpoint Manager Manually from the Client
Using High Security Mode
In high security mode, automatic discovery is disabled entirely; you must register the Tera2 PCoIP
Zero Client manually with the endpoint manager from the client.
Manual discovery requires a certificate
When manual discovery mode is used, DNS cannot be used to trust the endpoint manager. TheTera2 PCoIP Zero
Client must have been previously provisioned with a certificate using an endpoint manager.
For more information, see
To configure a PCoIP Zero Client with an endpoint manager using high security mode:
1. From the AWI, select Configuration > Management. The AWI Management page displays.
2. Set the Security Level option to High.
© 2020 Teradici
Discovering the Endpoint Manager Manually from the Client Using High Security Mode
The PCoIP Management Console's listening port is 5172. If you omit the port number,
Staging Clients Using an Endpoint
wss://<internal EM IP address/
Manager.