13. Expand Autoconnect Settings.
a. Click Enable to enable the autoconnect feature.
b. For Connection Trigger, select the option that describes the type of event that should
trigger the connection.
c. For Outbound Connection Type, select the option that describes the method used to
initiate the connection.
d. For Destination, enter the host name or IP address of the remote server. When using SSH,
this should be prefixed with the user name and followed by @.
e. For IP Port, enter the TCP port of the remote server (1-65535).
f. Click Enable TCP keepalive to enable TCP keepalive on the connection.
g. Click Enable TCP nodelay to enable TCP nodelay on the connection.
14. Expand Session Settings.
a. Enable Exclusive access to limit access to the serial port to a single active session.
b. For Escape sequence, type the characters used to start an escape sequence. If no
characters are defined, the escape sequence is disabled. The default is ~b.
c. For History size, type or select the number of bytes of output from the serial port that are
written to buffer. These bytes are redisplayed when a user connects to the serial port. The
default is 4000 bytes.
d. For Idle timeout, type the amount of time to wait before disconnecting due to user
inactivity.
15. Expand Monitor Settings.
a. Enable CTS to monitor CTS (Clear to Send) changes on this port.
b. Enable DCD to monitor DCD (Data Carrier Detect) changes on this port.
16. Click Apply to save the configuration and apply the change.
The Apply button is located at the top of the WebUI page. You may need to scroll to the top of
the page to locate it.