e. Flow control: For Flow control, select the type of flow control used by the device to
which you want to connect. The default is None.
7. Click Apply to save the configuration and apply the change.
The Apply button is located at the top of the WebUI page. You may need to scroll to the top of
the page to locate it.
  Command line
1. Log into the IX14 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. The serial port is enabled by default. To disable:
(config)> serial port1 enable false
(config)>
4. Set the mode:
(config)> serial port1 mode login
(config)>
5. (Optional) Set a label that will be used when referring to this port.
(config)>path-paramlabel label
(config)>
6. Set the baud rate used by the device to which you want to connect:
(config)>path-parambaudrate rate
(config)>
7. Set the number of data bits used by the device to which you want to connect:
(config)>path-paramdatabits bits
(config)>