Digi IX14 User Manual page 509

Hide thumbs Also See for IX14:
Table of Contents

Advertisement

Central management
3. Click Monitoring > Device event logs.
4. Click Enable event log uploads.
5. For Device event log upload interval, select the interval between health sample uploads.
6. Click Apply to save the configuration and apply the change.
  Command line
1. Log into the IX14 command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Device health data upload is enabled by default. To enable or disable:
To enable:
n
(config)> monitoring events enable true
(config)>
To disable:
n
(config)> monitoring events enable false
(config)>
4. The interval between event log uploads is set to 60 minutes by default. To change:
(config)> monitoring events interval value
(config)>
where value is one of 1, 5, 15, 30, or 60, and represents the number of minutes between
uploads of health sample data.
5. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
IX14 User Guide
Enable event log upload to Digi Remote Manager
509

Advertisement

Table of Contents
loading

Table of Contents