Measuring Adjacent Channel Leakage Ratio

1. Configure the mobile station to generate a 12.2 kbps reference measurement channel (RMC) uplink signal
on the correct frequency using the test set's FDD Test operating mode.
2. Press the
Measurement selection
3. Select the Adjacent Channel Leakage Ratio measurement.
4. Press the ACLR Setup (
5. Set the measurement parameters as needed for your measurement situation, such as turning the
measurements on or off for the different frequency offsets.
6. Press the Change View (
7. If using the graphical display, press Graph Limits (
the four frequency offsets (shown in the graphical measurements example below as the thin lines above
each measurement).
Typical adjacent channel leakage ratio results using graphical and numeric format.
key.
) key.
F1
) key to display the measurement results in either graphical or numeric format.
F2
S:\Hp8960\E1963A WCDMA\3.2 release\Reference Guide\Chapters\wcdma_man_measurements.fm
WCDMA Measurements Using FDD Test Operating Mode
) to enter the pass/fail measurement limit for each of
F5
423