FETCh:WWQuality
FETCh:WWQuality:EVM[:MAXimum]?
Function
Queries the maximum EVM.
Query
Range: 0 to 99%, 9.91 E+37
Resolution: 0.1
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"FETCH:WWQUALITY:EVM:MAXIMUM?" !Returns maximum EVM.
FETCh:WWQuality:EVM:ALL?
Function
Queries the EVM measurements.
Results are returned in the following order: minimum, maximum, average, standard deviation
error vector magnitude.
Query
Minimum EVM
• Range: 0 to 99%, 9.91 E+37
• Resolution: 0.1
Maximum EVM
• Range: 0 to 99%, 9.91 E+37
• Resolution: 0.1
Average EVM
• Range: 0 to 99%, 9.91 E+37
• Resolution: 0.1
Standard Deviation EVM
• Range: 0 to 99%, 9.91 E+37
• Resolution: 0.01
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"FETCH:WWQUALITY:EVM:ALL?" !Returns all EVM measurement results.