Error Message
+113 Internal error; <VI NAME> forced inactive
+114 Internal error; <VI NAME> not responding
+115 Internal error; <VI NAME> inactive
+120 Warning; Receiver over range due to requested
settings
+121 Warning; Receiver under range due to requested
settings
+122 Warning; Reference out of lock
+123 Warning; Duplicate RF IN/OUT Amplitude Offset
Frequency entry. First frequency entry in RF IN/OUT
Amplitude Offset table will be used.
+124 Warning; Source over range due to requested
settings
+125 Warning; Source under range due to requested
settings
+130 Configuration error; Unable to switch to indicated
Test Application
+131 Configuration error; Current Test Application is
not licensed (License = N). Select another Test
Application
Description
Indicates that a VI is inactivated when not executed.
<VI NAME> includes : "IntVmVI","GprsBsEmulVI",
"GsmComBsEmulVI","GSMFixedVI", "MiscVI",
"GSMSacchMriVI", "IQSelfCalVI1", "IQSelfCalVI2",
"TA RevisionVI", "TdmaTaBsEmulVI".
Indicates that a VI has not been instantiated or the
state is not available.
<VI NAME> includes : "IntVmVI","GprsBsEmulVI",
"GsmComBsEmulVI", "GSMFixedVI", "MiscVI",
"GSMSacchMriVI", "IQSelfCalVI1", "IQSelfCalVI2",
"TA RevisionVI", "TdmaTaBsEmulVI" ,
"RfHwAccessVI".
Indicates that a VI has been made inactive.
<VI NAME> includes : "IntVmVI", "GSMFixedVI",
"MiscVI", "GSMSacchMriVI", "IQSelfCalVI1",
"IQSelfCalVI2", "TA RevisionVI".
Indicates the total received power (a combination of
received power and amplitude offset) is above the
range of the test set.
Indicates the total received power (a combination of
received power and amplitude offset) is below the
range of the test set.
Indicates the test set's internal reference is out of lock.
Indicates that an amplitude offset value for that
frequency has already been entered. The test set will
use the amplitude offset value entered first.
The setting selected for total transmit power (a
combination of cell power, awgn power, amplitude
offset) is above the test set's range.
The setting selected for total transmit power (a
combination of cell power, awgn power, amplitude
offset) is below the test set's range.
The test application selected is not available for this
test set.
The test application selected is not licensed. Select
another revision or test application that is licensed
(License = L).