Agilent Technologies 8960 Series Reference Manual page 213

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

CALL:STATus:OCNSource[:LEVel]?
Function
Queries the orthogonal channel noise source (OCNS) level for the selected system type.
The OCNS level is set using the
The optional [:SELected] keyword in this command specifies that the OCNS channel level being
queried applies to the current system type.
Query
Range: 0 to -20 dB, 9.91 E+37
Resolution: 0.01 dB
*RST Setting
9.91 E+37
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"CALL:STATUS:OCNSOURCE:LEVEL?"
CALL:STATus:OCNSource:STATe?
Function
Queries the current on/off state of the orthogonal channel noise simulator channel (OCNS).
The OCNS channel on/off state is set using the
The optional [:SELected] keyword in this command specifies that the OCNS channel state being
queried applies to the current system type.
Query
Range: 1|0
*RST Setting
0 (off)
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"CALL:STATUS:OCNS:STATE?"
CALL:STATus:PICHannel[:LEVel]?
Function
Queries the current downlink page indicator channel's power.
Query
Range: -20.00 to 0 dB, 9.91 E+37
Resolution: 0.01 dB
*RST Setting
9.91 E+37
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"CALL:STATUS:PICHANNEL:LEVEL?"
"CALL:OCNSource"
commands.
"CALL:OCNSource"
S:\Hp8960\E1963A WCDMA\3.2 release\Reference Guide\Chapters\wcdma_hpib_call_status.fm
CALL:STATus
commands.
213