CALL[:CELL]:POWer:AMPLitude[:SELected]
Function
Sets/queries the cell power level (including compensation for amplitude offset).
The optional [:SELected] keyword in this command specifies that the cell power level being set or
queried applies to the current system type. The current system type can be changed using the
"CALL[:CELL]:SYSTem[:TYPE]?"
Setting
Range:
• -170dBm/3.84MHz to +37dBm/3.84MHz, 9.91 E+37
(-120 dBm/3.84MHz to -13 dBm/3.84MHz actual hardware range with amplitude offset = 0)
The actual power range is defined by adding the value of the associated Amplitude Offset to
the range in the table. For example, if amplitude offset is -3.5 dB, then the power range will be
-123.5 dBm/3.84 MHz to -16.5 dBm/3.84MHz.
Resolution: 0.01 dBm/3.84 MHz
Query
Range: Same as setting range.
Resolution: Same as setting range.
*RST Setting
9.91 E+37
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"CALL:CELL:POWER:AMPLITUDE -30"
!Sets the cell power level -30 dBm.
CALL[:CELL]:POWer:STATe[:SELected]
Function
Sets/queries the cell power state.
The optional [:SELected] keyword in this command specifies that the cell power state being set or
queried applies to the current system type. The current system type can be changed using the
"CALL[:CELL]:SYSTem[:TYPE]?"
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
ON
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"CALL:CELL:POWER:STATE OFF" !Turns off cell power.