WCDMA and FDD Manual User Messages
Table 9.
Error Message
Channel power calibration completed successfully.
Channel power calibration failed due to temperature
drift. Wait for temperature to stabilize.
Channel power calibration failed due to oven out of
range.
Channel power calibration failed due to loopback switch
problem.
Channel power calibration failed due to under range
condition.
Channel power calibration failed due to over range
condition.
Channel power calibration failed due to correlation
problem.
Channel power calibration failed.
Channel power calibration in progress. Do not apply RF
power during calibration
Channel power calibration <x>%.
FDD measurement warning; Thermal Power
measurement has been closed.
FDD measurement warning; Adjacent Channel Leakage
Ratio measurement has been closed.
FDD measurement warning; Waveform Quality
measurement has been closed.
FDD measurement warning; Average Power
measurement has been closed.
FDD measurement warning; Loopback Bit Error Ratio
measurement has been closed.
Description
The calibration procedure for the channel power and
adjacent channel leakage ratio (ACLR) measurements
completed without problems.
The temperature in the test set was changing during
calibration, causing the calibration to fail.
Indicates an internal problem during measurement
calibration.
Indicates an internal problem during measurement
calibration.
Indicates an internal problem during measurement
calibration.
Indicates an internal problem during measurement
calibration.
Indicates an internal problem during measurement
calibration.
The measurement calibration procedure failed for an
unspecified reason.
Tells you to not apply power during measurement
calibration.
Progress indicator for the measurement calibration routine.
Indicates that a measurement has been inactivated because
of a resource conflict. This message is typically generated
when thermal power measurements are initiated.
Indicates that a measurement has been inactivated because
of a resource conflict. This message is typically generated
when adjacent channel leakage ratio measurements are
initiated.
Indicates that a measurement has been inactivated because
of a resource conflict. This message is typically generated
when waveform quality measurements are initiated.
Indicates that a measurement has been inactivated because
of a resource conflict. This message is typically generated
when average power measurements are initiated.
Indicates that a measurement has been inactivated because
of a resource conflict. This message is typically generated
when loopback bit error ratio measurements are initiated.