Agilent Technologies 8960 Series Reference Manual page 280

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

RFANalyzer
RFANalyzer:MANual:UPLink[:MFRequency]
Function
The setting form of this command performs two functions: (1) sets the tune frequency of the test
set's demodulation signal path, and (2) selects manual tune mode for the test set's demodulation
signal path.
The query form of this command returns the tune frequency of the test set's demodulation signal
path.
The tune mode for the test set's demodulation path can be returned to auto using the
"RFANalyzer:CONTrol:UPLink:FREQuency:AUTO"
Setting
Range: 292.5 MHz to 2700 MHz
Resolution: 0.1 Hz
Query
Range: 292.5 MHz to 2700 MHz
*RST setting
896 MHz
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"RFANALYZER:MANUAL:UPLINK:MFREQUENCY 1955.030 MHZ"
!Enables manual control of the demodulation signal path tune frequency and sets the tune frequency
!to 1955.030 MHz.
RFANalyzer:MANual:UPLink:FREQuency
Function
Sets/queries the tune frequency of the test set's demodulation signal path.
This setting is applied when manual mode is selected (see
"RFANalyzer:CONTrol:UPLink:FREQuency:AUTO"
Setting
Range: 292.5 MHz to 2700 MHz
Resolution: 0.1 Hz
Query
Range: 292.5 MHz to 2700 MHz
*RST setting
896 MHz
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"RFANALYZER:MANUAL:UPLINK:FREQUENCY 942.6 MHZ"
!Sets the test set's demodulation signal path tune frequency to 942.6 MHz.
280
S:\Hp8960\E1963A WCDMA\3.2 release\Reference Guide\Chapters\wcdma_hpib_rfanalyzer.fm
command.
).