Agilent Technologies 8960 Series Reference Manual page 216

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

CALL:TOTal:POWer
CALL:TOTal:POWer:STATe?
Function
Queries the total RF power state for the current system type.
The total RF power state is 1 (on) if either cell power or AWGN power is on.
The return value for this query is not necessarily the total power state at the moment this
command is processed by the test set. This command may return a state that has been requested
of the test set, but that has been pended or delayed for some reason. To query the power state of
the test set at the moment, use the
Query
Range: 1|0
*RST Setting
0 (off)
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"CALL:TOTAL:POWER:STATE?"
216
S:\Hp8960\E1963A WCDMA\3.2 release\Reference Guide\Chapters\wcdma_hpib_call_total_power.fm
"CALL:STATus:TOTal:POWer:STATe?"
command.