CALL:FDDTest
CALL:FDDTest:CLPControl:UPLink:MODE
Function
Sets/queries the uplink inner loop power control mode.
When UP is selected, the test set sends all 0 (up) power control bits.
When DOWN is selected, the test set sends all 1 (down) power control bits.
When UDOWn is selected, the test set sends alternating up/down power control bits.
When UDOWn10 is selected, the test set sends alternating 10 up/down power control bits.
Setting
Range: UP|DOWN|UDOWn|UDOWn10
Query
Range:UP|DOWN|UDOW|UDOW10
*RST Setting
UDOW
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"CALL:CELL:CLPCONTROL:REVERSE:MODE UDOWN"
!Sets the closed loop power control mode to alternating up, down bits.
CALL:FDDTest:CCPChannel:PRIMary:STATe
Function
Sets/queries the primary common control physical channel's state in test mode.
Setting
Range: 1|ON|0|OFF
Query
Range: 1|0
*RST Setting
1 (on)
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"CALL:FDDTEST:CCPCHANNEL:PRIMARY:STATE ON"
CALL:FDDTest:CPIChannel[:SLEVel]
Function
Sets/queries the test mode power offset of the common pilot channel . This command sets the
power offset level and turns on the power offset.
Setting
Range: -20.00 dB to 0 dB
Resolution: 0.01
Query
Range: -20.00 dB to 0 dB
Resolution: 0.01
*RST Setting
-3.3 dB
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"CALL:FDDTEST:CPICHANNEL:SLEVEL -10"