"Diagram Conventions" on page 168
CALL:OCNSource:LEVel?
Function
Queries the calculated level of the UTRA FDD composite orthogonal channel noise simulator
(OCNS).
The OCNS level is a calculated value used to balance the relative power levels of the following
channels to sum to 100%:
• OCNS
• Common Pilot Channel (CPICH)
• Primary Common Control Physical Channel (P-CCPCH
• Synchronization Channel (SCH)
• Page Indicator Channel (PICH)
• Dedicated Physical Channel (DPCH)
If the contribution of OCNS is calculated to be -30 dB or less, the OCNS state is turned off.
Query
Range: 0 to -29 dB, 9.91 E+37
Resolution: 0.01 dB
*RST Setting
9.91 E+37
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"CALL:OCNSOURCE:LEVEL?" !Queries the calculated OCNS level.
:LEVel?
(returns num value)
:STATe?
(returns 1||0)