Agilent Technologies 8960 Series Reference Manual page 355

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

STATus:QUEStionable:CALL:TA2000 Condition Register Bit Assignment
The STATus:QUEStionable:CALL:TA2000 registers will contain information about which event(s) occurred
during call processing that indicate what call processing procedure failed
Bit
Binary
Number
Weighting
15
32768
14
16384
13
8192
12
4096
11
2048
10
1024
9
512
8
256
7
128
6
64
5
32
4
16
3
8
2
4
1
2
0
1
Program Example - STATus:QUEStionable:CALL:TA2000 Register Bit Assignment
OUTPUT 714;"STATUS:QUESTIONABLE:CALL:TA2000:EVENT?"
!Queries and clears the Questionable Call Event Register
OUTPUT 714;"STATUS:QUESTIONABLE:CALL:TA2000:CONDITION?"
!Queries and clears the Questionable Call Condition Register
OUTPUT 714;"STATUS:QUESTIONABLE:CALL:TA2000:ENABLE 1024"
!Sets the Questionable Call Enable Register for bit 10
OUTPUT 714;"STATUS:QUESTIONABLE:CALL:TA2000:NTRANSITION 2"
!Sets the Questionable Call Negative Transition Filter Register for bit 1
OUTPUT 714;"STATUS:QUESTIONABLE:CALL:TA2000:PTRANSITION 2"
!Sets the Questionable Call Positive Transition Filter Register for bit 1
Condition
Not Used. Defined by SCPI.
MUI Maskable Message.
Reserved for future use.
Reserved for future use.
Reserved for future use.
Reserved for future use.
Reserved for future use.
Reserved for future use.
Reserved for future use.
Reserved for future use.
Reserved for future use.
MS reject order received
Carrier not detected on new
channel
Handoff completion not received
Release order not received
Extension Bit
S:\Hp8960\E1963A WCDMA\3.2 release\Reference Guide\Chapters\wcdma_hpib_status_questionable.fm
Description
This bit is always 0.
This bit is always 0.
This bit is always 0.
This bit is always 0.
This bit is always 0.
This bit is always 0.
This bit is always 0.
This bit is always 0.
This bit is always 0.
This bit is always 0.
This bit is a 1 if the Service Option or Radio
Configuration change was rejected by the MS while
connected.
This bit is a 1 when no power is detected by the test
set after a handoff or when making a call.
This bit is a 1 if the test set does not receive a
handoff completion message from the MS.
This bit is a 1 if the MS does not send the call release
to the test set.
This bit is always 0.
STATus:QUEStionable