Step 6: Reconfigure Test Set and Mobile Station Connection Parameters
Figure 8.
Process for Performing a Handoff (Handover)
Start
Send commands to
change channel.
Send the CALL:STAT?
query command.
Enter response from
CALL:STAT? query.
No
Call connected?
Yes
Proceed with control
Send CALL:END
program.
command.
Invoke error
handler.
Test Mode Considerations In test mode, you can either change the test set's frequencies by using the
handoff (handover) commands, or directly control the RF generator and RF analyzer.
In either case, you must also send the appropriate test mode commands to the mobile station to move it to the
new channel.
Change Other Connection Parameters
You may also choose to change the mobile station transmit power level or cell power, or other connection
parameters such as timeslot or timing advance.