FETCh:AFANalyzer:SINAD:MAXimum?
Function
Queries the maximum SINAD measurements.
Query
Range: -99 to 99 dB, 9.91 E+37
Resolution: 0.01 dB
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"FETCH:AFANALYZER:SINAD:MAXIMUM?"
FETCh:AFANalyzer:SINAD:MINimum?
Function
Queries the minimum SINAD measurements.
Query
Range: -99 to 99 dB, 9.91 E+37
Resolution: 0.01 dB
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"FETCH:AFANALYZER:SINAD:MINIMUM?"
FETCh:AFANalyzer:SINAD:SDEViation?
Function
Queries the standard deviation SINAD measurements.
Query
Range: 0 to 99 dB, 9.91 E+37
Resolution: 0.001 dB
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"FETCH:AFANALYZER:SINAD:SDEVIATION?"
FETCh:AFANalyzer:VOLTage[:AVERage]?
Function
Queries the average audio level measurement.
Query
Range: 0 to 20 volts, 9.91 E+37
Resolution: the lesser of 4 significant digits or 10 uV
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"FETCH:AFANALYZER:VOLTAGE:AVERAGE?"
S:\Hp8960\E1963A WCDMA\3.2 release\Reference Guide\Chapters\wcdma_hpib_fetch_afan.fm
FETCh:AFANalyzer
231

Advertisement

Table of Contents
loading

Table of Contents