Agilent Technologies 8960 Series Reference Manual page 242

Hide thumbs Also See for 8960 Series:
Table of Contents

Advertisement

FETCh:WCPower
FETCh:WCPower:POWer:MINimum?
Function
Queries the minimum power of several channel power measurements. To set the number of
measurement to compare, use the command
Query
• Range: -99 to 99 dBm, 9.91 E+37
• Resolution: 0.01 dB
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"FETCH:WCPOWER:POWER:MINIMUM?"
!Queries the minimum channel power.
FETCh:WCPower:POWer:SDEViation?
Function
Queries the standard deviation of several channel power measurements. To set the number of
measurement to compare, use the command
Query
• Range: 0 to 99 dB, 9.91 E+37
• Resolution: 0.001 dB
Requirements
Test Application Revision: A.02.00 and above
Programming Example
OUTPUT 714;"FETCH:WCPOWER:POWER:SDEVIATION?"
!Queries the standard deviation of power for the channel power measurements.
242
S:\Hp8960\E1963A WCDMA\3.2 release\Reference Guide\Chapters\wcdma_hpib_fetch_wcpower.fm
"SETup:WCPower:COUNt[:SNUMber]" on page
"SETup:WCPower:COUNt[:SNUMber]" on page
304.
304.

Advertisement