Cab Display Module (Cdm) Error Codes - MacDon M105 Operator's Manual

Self-propelled windrower
Table of Contents

Advertisement

9 Cab Display Module (CDM) Error Codes

NOTE:
In the case of dual codes being shown for an item (primarily the solenoid valves), the first code indicates a
SHORT CIRCUIT condition, while the second code indicates an OPEN CIRCUIT condition. IE. E41 would be a
SHORT in the Reel Aft solenoids (P55, P59), while E141 would indicate an OPEN circuit.
Codes
E1
E2
RTCH NOT ALLOWED
E3
E4
E5
E6
TEMP GAUGE SHORT
E7
SPEED STICK SHORT
HEADER ENABLE SHORT
E8
E9
E10
CDM INTERNAL ERROR
E11
CDM POWER UP
E12
E13
FUEL SOLENOID
E24
E124
DECK SHFT RIGHT P95
E25
E125
DECK SHFT LEFT P96
E26
E27
E28
E128
TILT P2A
E29
E129
TILT P4C
E30
E130
4 WAY VALVE P5A
E31
E131
BYPASS VALVE P1
E32
E132
HEADER UP/DOWN P4A
E33
E133
SCREEN CLEANERS
E34
E134
RIGHT STOP LAMP
E35
E135
LEFT STOP LAMP
E36
E136
RIGHT TURN LAMP
E37
E137
LEFT TURN LAMP
E38
E39
E40
E140
HIGH RANGE P5B
169890
CDM Display
Error Codes E14 to E23 not allocated
Return To Cut activated with the header off.
Wiring / connection problem.
Wiring / connection problem.
Wiring / connection problem.
Internal hardware or software problem.
CDM Module did not power up correctly.
WCM Fuel solenoid output fault detected.
Right Deck Shift solenoid P95 fault detected
Left Deck Shift solenoid P96 fault detected
Header Tilt solenoid P2A (V2A) fault detected
Header Tilt solenoid P4C (V4C) fault detected
4 Way valve solenoid P5A (V5A) fault detected
Bypass valve solenoid P1 (V1) fault detected
Header up / down solenoid P4A (V4A) fault detected
Screen cleaner output fault detected
Right stop lamp output fault detected
Left stop lamp output fault detected
Right turn lamp output fault detected
Left turn lamp output fault detected
High range solenoid P60 fault detected
359
Description
Revision A

Advertisement

Table of Contents
loading

Table of Contents