MacDon M105 Operator's Manual page 83

Self-propelled windrower
Table of Contents

Advertisement

Display (A)
LOW HYDRAULIC OIL
NO OPERATOR
NOT IN PARK
TRANS OIL PRESS
TRANS OIL TEMP
##.# LOW VOLTS
##.# HIGH VOLTS
169890
OPERATOR'S STATION
Flashing
Alarm Tone
Continuous loud tone for 5
seconds: if condition not
X
rectified, single loud tone every
5 minutes
Continuous tone
X
Short beep with each flash
Continuous loud tone until oil
X
pressure is regained
Ongoing intermittent moderate
X
tone until temperature is below
acceptable level
short beep every 2 seconds:
X
flashes every second
short beep every 2 seconds:
X
flashes every second
Description
Low hydraulic oil level, header
shuts down automatically if
engaged: HEADER DRIVE switch
must be moved to OFF position
and then to ON position to restart
the header
Operator not detected in seat
with header engaged or out of
N-DETENT: engine shutdown
after 5 seconds
GSL or interlock switches not
closed with key ON / engine OFF
Low transmission charge oil
pressure
Transmission oil temperature
above 221°F (105°C)
Voltage below 11.5
Voltage above 15.5
69