Symptom
Problem
Low battery output
Loose or corroded battery
connections
Controls not in NEUTRAL
Starter cranks
slowly or will not
Relay not functioning
operate
Main fuse defective/blown
Key power fuse blown
Key switch worn or terminals
loose
Switch at Interlock not closed
or defective
Crankcase oil too high
viscosity
Air filters require
Aspirator plugged
frequent cleaning
169890
TROUBLESHOOTING
Solution
Check battery charge.
Clean and tighten loose connections.
Move GSL to NEUTRAL.
Move steering wheel to CENTER
position.
Disengage header.
Check relay and wire connections.
Replace main fuse.
Replace.
Contact Dealer.
Adjust switch or replace. Contact your
Dealer.
Use recommended oil.
Clean out aspirator.