Ricoh Taurus-C1a Technical Bulletin page 10

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Reissued: 20-Apr-15
Model:
Taurus-C1a/C1b
Version
December 2012, the AC power supply unit must be installed (See RTB#
RD074097).
Engine
System/Copy
OpePanel.EXP
Language Install
Web Support
Specification Changes
1. The default value of the following SP was changed from "0" to "1".
SP2-830-001 AC Transcription Power Pack
Symptoms Corrected
1. Jam 009 occurs in copy operation when selecting a different paper for the
2. SC280 occurs in copy operation when the original contains B/W and Color
1.62:04
Symptom Corrected
1. The jams on BK5030 when using CF5030
2. Invalidity of Adjustment Settings for Operators #0405 (Adjust Punch
3. BK204 error on BK5030 during long running job
1.61:04
Symptom Corrected
IMPORTANT
Change the value in SP3-820-022 to "0"after upgrading the firmware.
1.60:04
Specification Changes
The default values for the following SPs were modified to reduce "shock jitter".
SP 1022-002 -70 -> -120
Symptom Corrected
The low productivity when making booklets with Plockmatic.
1.59:04
Specification Changes
The behavior of SP1-004-003 was modified to prevent Jam27/29.
Symptom Corrected
Subcodes of SC682 are not displayed.
1.58:04
Firmware requirements
Be sure to upgrade all the firmwares listed in the following table together as a
set.
echnical
T
Modified Points or Symptom Corrected
Firmware
1.63.04 or newer
1.11 or newer
1.11 or newer
1.07 or newer
1.09 or newer
front cover.
and certain settings such as A3/DLT, 2-sided are applied.
Position With Feed Direction) when switching the main power off/on or
recovering from energy save mode
SC36x caused by bug
Modification of toner refresh mode algorithm
(The toner yield becomes longer by new refresh mode algorithm under low
coverage conditions.)