Ricoh Taurus-C1a Technical Bulletin page 280

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Model:
Taurus-C1a/C1b/P1 (D074/D075/M044)
Modification Procedure
Follow the procedure below for EVERY drum cleaning unit; YMCK.
Work time is approximately 10 minutes per station.
1. Removing the component parts
echnical
T
B
ulletin
Date:
13-Jun-12
1-1. Remove the apply blade.
1-2. Remove the stay.
1-3. Lift up the areas marked
with red circles to release
the pressure, and then,
remove the lubricant bar.
Stay
Modified in step 2
Sheet Mylar
Peeled off in step 3