Ricoh Taurus-C1a Technical Bulletin page 440

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Reissued:30-Jan-14
Model:
Taurus-C1/P1 (D074/D075/M044)
RTB Reissue
The items in
bold italics
Subject:
Notes on cleaning the ITB speed sensors
From:
1
PP Tech Service Sec., PP Tech Service Dept.
st
Classification:
Steps to execute SP2920 were added in the revision.
Reason: SP2920-001 is needed to initialize the position of the ITB after its replacement and
cleaning/replacement of the feedback sensor.
This RTB has been issued to announce the important notes on cleaning the ITB speed
sensor to prevent SC499-40 as a result of carrying out cleaning incorrectly.
The following procedure is recommended when cleaning the two ITB speed sensors
indicated in yellow in the photo below:
1. Use a vacuum cleaner or an air blower to remove dust.
2. Wipe the sensors with a wet cotton swab. If a cotton swap is not at hand, wipe the
sensors with a wet cloth. Use water if necessary, but DO NOT use solvent of any type
(ethanol, etc).
Note:
DO NOT scrub with force or apply cloth to the tip of a screwdriver when cleaning the
sensors. Doing so could scrape off the coated surface and disable proper detection
because the surface of the sensor is coated with slits that correspond to the slits on the
ITB.
The ITB speed sensor was modified to prevent dust from getting inside the sensor by
improving the sealing. (P/N of the new ITB speed sensor: D0746208)
echnical
T
were added.
Troubleshooting
Mechanical
Paper path
Product Safety
ulletin
B
Date:
3-Jul-12
Prepared by:
Part information
Electrical
Transmit/receive
Other (
)
PAGE: 1/2
No.:
RD074077b
K. Tsutsui
Action required
Service manual revision
Retrofit information
Tier2

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Taurus-c1b

Table of Contents