Ricoh Taurus-C1a Technical Bulletin page 243

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Model:
Taurus-C1a/C1b
Subject:
Procedure for Replacing the Development Roller
Seals
From:
1st PP Tech Service Sec., PP Tech Service Dept.,
Classification:
Please add to your field service manual the following procedures for replacing the
development roller seals.
! D0743343 SEAL:DEVELOPMENT ROLLER:FRONT
! D0743344 SEAL:DEVELOPMENT ROLLER:REAR
Procedure
Replacing the FRONT Seal (D0743343: SEAL:DEVELOPMENT ROLLER:FRONT)
1. Pull out the PCDU according to the procedure in the service manual in the section:
4. Replacement and Adjustments > Common Procedures > Removing PCDUs
[A]
2. Remove the old seal [A] and clean the surface of the area where the seal was attached.
Note
The seal consists of two parts; the black part and the transparent part. (See the diagram
above.) Make sure to remove the whole seal.
echnical