Taurus-C1/P1 (D074/D075/M044)
Procedure: Peeling Off the Bottom Mylar
BEFORE Bottom Mylar Removal
Feed Direction
Step 1. Pull out the ITB unit by referring to the procedure described in the service
manual.
Step 2. Remove D0746122
from the ITB unit.
a. Remove the screw. (x1)
T
echnical
Remove this Mylar.
(GUIDE: TRANSPORT: INTERMEDIATE TRANSFER: ASS'Y)
ITB Unit
D0746122
B
ulletin
Date:
25-Aug-11
AFTER Bottom Mylar Removal
Feed Direction
b. Pull out the guide plate forwards in
the direction of the red arrow while
supporting the plate from the bottom
with the other hand.
PAGE: 6/9
No.: