Model:
Taurus-C1 (D074/D075)
Correction 7: Added Missing Descriptions in SC Tables
Troubleshooting > SC Tables
Descriptions in
red
SC260
SC262
SC576
SC579
T
echnical
have been added and corrected for the following SC tables:
C
Laser Thermistor Error (C/K)
C
Laser Thermistor Error (Y/M)
One of the following occurred:
• The reading of the thermistor in the
less than 10°C (50°F), indicating that the thermistor
has disconnected.
• The reading of the thermistor in the
more than 80°C (176°F), indicating that the thermistor
has shorted out.
• Cycle the machine off/on
• IOB harness loose, disconnected, broken, defective
•
CK/YM
laser unit defective
• IOB defective
A
Hot Roller NC Sensor (Sensor 7) Poor Connection
The hot roller NC sensor (infrared thermistor) on top of
the fusing unit detected temperature less than 0C for 75
sec.
•
Do SP5810 to cancel the fatal error
•
Sensor disconnected
•
Sensor connector harness or connector broken or
defective
A
Thermistor 8 Error:
Temperature detected at less than 0°C.
Note: This is the contact thermistor at the top rear of the
fusing unit
• Do SP5810 to cancel the fatal error
• Harness disconnected or broken
• Poor contact with surface of heating roller
• Thermistor defective
B
ulletin
Date:
22-Jun-2011
Poor
Connection
PAGE: 11/14
No.:
RD074015a
CK/YM
laser unit was
CK/YM
laser unit was