Ricoh Taurus-C1a Technical Bulletin page 31

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

Model:
Taurus-C1 (D074/D075)
Correction 7: Added Missing Descriptions in SC Tables
Troubleshooting > SC Tables
Descriptions in
red
SC260
SC262
SC576
SC579
T
echnical
have been added and corrected for the following SC tables:
C
Laser Thermistor Error (C/K)
C
Laser Thermistor Error (Y/M)
One of the following occurred:
• The reading of the thermistor in the
less than 10°C (50°F), indicating that the thermistor
has disconnected.
• The reading of the thermistor in the
more than 80°C (176°F), indicating that the thermistor
has shorted out.
• Cycle the machine off/on
• IOB harness loose, disconnected, broken, defective
CK/YM
laser unit defective
• IOB defective
A
Hot Roller NC Sensor (Sensor 7) Poor Connection
The hot roller NC sensor (infrared thermistor) on top of
the fusing unit detected temperature less than 0C for 75
sec.
Do SP5810 to cancel the fatal error
Sensor disconnected
Sensor connector harness or connector broken or
defective
A
Thermistor 8 Error:
Temperature detected at less than 0°C.
Note: This is the contact thermistor at the top rear of the
fusing unit
• Do SP5810 to cancel the fatal error
• Harness disconnected or broken
• Poor contact with surface of heating roller
• Thermistor defective
B
ulletin
Date:
22-Jun-2011
Poor
Connection
PAGE: 11/14
No.:
RD074015a
CK/YM
laser unit was
CK/YM
laser unit was