3. Attach the new seal while checking the following points.
! Corner [D] of the seal aligns with the corner [E] of the frame.
! Area [B] of the seal is firmly attached.
! Edge [A] of the seal is attached to the doctor blade and is not positioned in the
gap between the doctor blade and the development roller.
! The transparent part of the seal [C] is attached properly along the curve of the
roller.