< SC Tables \ SC500: Paper Feed, Transport, Duplexing >
SC576 added
SC576
A
Hot Roller NC Sensor (Sensor 7) Poor Connection
The hot roller NC sensor (infrared thermistor) on top of the fusing unit detected temperature
less than 0C for 75 sec.
Do SP51810 to cancel the fatal error
Sensor disconnected
Sensor connector harness or connector broken or defective
< SC Tables \ SC600: Communications >
SC652 added
SC652
B
@Remote Service ID2 Mismatch Error 1
One of the following problems occurred with ID2 stored in NVRAM:
・ A control board from another machine where Cumin was set up was installed in this
machine.
・ NVRAM was replaced with the NVRAM from another machine.
・If Cumin has already been installed, confirm that the NVRAM is compatible for use with
Cumin.
・If Cumin has just been installed, confirm that the NVRAM is compatible for use with
Cumin, clear the Cumin setting, set the common authentication, then try again.
< SC Tables \ SC900: Other >
SC994 added
SC994
C
Operation Panel Management Records Exceeded
An error occurred because the number of records exceeded the limit for images managed in
the service layer of the firmware. This can occur if there if there are too many application
screens open on the operation panel.
・ No action required because this SC does not interfere with operation of the machine.
T
B
echnical