Ricoh Taurus-C1a Technical Bulletin page 283

Hide thumbs Also See for Taurus-C1a:
Table of Contents

Advertisement

echnical
ulletin
T
B
PAGE: 6/6
Model:
Date:
No.:
Taurus-C1a/C1b/P1 (D074/D075/M044)
13-Jun-12
RD074074
4. Attaching the anti-vibration cushion D0742510
Clean the surface of the back side of the frame and attach the cushions D0742510 (2 pcs)
as shown below.
11mm
IMPORTANT
These cushions need to be replaced at 300Kp (135000m) as they will wear over time.
Combine the PM for this part with other components of the drum cleaning unit that also
require replacements at 300Kp.
NOTE: To prevent waste toner from spilling, attach the cushions with the drum cleaning unit set on the
mainframe slide-rails.
To complete the procedure
Check the values set in SP7940-013, 020, 027, 034 (Drive Distance: End Std Value: K, C,
M, Y). If these values were previously changed to "67500" (half of the original yield), reset
the values to the original yield "135000".